| HP ProCurve Switch 2524 (J4813A) | HP ProCurve Switch 2512 (J4812A) |
|---|
| Ports |
| 24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 open transceiver slots
1 RS-232C DB-9 console port
| 12 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 open transceiver slots
1 RS-232C DB-9 console port
|
| Physical characteristics |
| Dimensions | 8.0(d) x 17.4(w) x 1.8(h) in. (20.32 x 44.2 x 4.57 cm) (1U height) | 8.0(d) x 17.4(w) x 1.8(h) in. (20.32 x 44.2 x 4.57 cm) (1U height) |
| Weight | 6.0 lb. (2.72 kg), Fully loaded | 6.0 lb. (2.72 kg), Fully loaded |
| Memory and processor |
| Processor | ARM7TDMI @ 62.5 MHz, 2 MB flash, 26 KB RAM/ROM capacity; packet buffer size: 6 MB | ARM7TDMI @ 62.5 MHz, 2 MB flash, 26 KB RAM/ROM capacity; packet buffer size: 6 MB |
| Mounting |
| Mounts in a standard 19 in. rack (hardware included)
| Mounts in a standard 19 in. rack (hardware included)
|
| Performance |
| Latency | < 10 µs (LIFO) | < 10 µs (LIFO) |
| Throughput | 6.6 million pps (64-byte packets) | 4.8 million pps (64-byte packets) |
| Switching capacity | 9.6 Gbps | 9.6 Gbps |
| MAC address table size | 4,096 entries | 4,096 entries |
| Environment |
| Operating temperature | 32ºF to 131ºF (0ºC to 55ºC) | 32ºF to 131ºF (0ºC to 55ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 90% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Shock and vibration | HP759, HP760 (similar to EN 60068, IEC 68) | HP759, HP760 (similar to EN 60068, IEC 68) |
| Electrical characteristics |
| Maximum heat dissipation | 123 BTU/hr (130 kJ/hr) | 123 BTU/hr (130 kJ/hr) |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 2.4 / 1.2 A | 2.4 / 1.2 A |
| Maximum power rating | 36 W | 36 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition
| cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition
|