| HP ProCurve Switch 8108fl (J8727A) | HP ProCurve Switch 8116fl (J8728A) |
|---|
| Included accessories |
| 1 HP ProCurve Switch fl Redundant Management Module (J8731A)
1 HP ProCurve 8108fl Redundant Switch Fabric Module (J8729A)
1 HP ProCurve Switch fl Redundant Power Supply (J8732A)
| 1 HP ProCurve Switch fl Redundant Management Module (J8731A)
1 HP ProCurve 8116fl Redundant Switch Fabric Module (J8730A)
2 HP ProCurve Switch fl Redundant Power Supply (J8732A)
|
| Ports |
| 8 open module slots
Supports a maximum of 80 auto-sensing 100/1000 ports or 16 10-GbE ports or 80 mini-GBICs, or a combination
| 16 open module slots
Supports a maximum of 160 auto-sensing 100/1000 ports or 32 10-GbE ports or 160 mini-GBICs, or a combination
|
| Power supplies |
| includes: 1 x J8732A
2 open power supply slots
| includes: 2 x J8732A
1 open power supply slots
|
| Physical characteristics |
| Dimensions | 21.5(d) x 17.3(w) x 22.7(h) in. (54.61 x 43.94 x 57.66 cm) (13U height) | 21.5(d) x 17.3(w) x 34.8(h) in. (54.61 x 43.94 x 88.39 cm) (20U height) |
| Weight | 219.7 lb. (99.66 kg)1 8-slot chassis, 2 switch fabric modules, 2 management modules, 2 fan trays, 3 power supplies, 8 internal modules, Fully loaded | 340 lb. (154.22 kg)1 16-slot chassis, 2 switch fabric modules, 2 management modules, 2 fan trays, 3 power supplies, 16 internal modules, Fully loaded |
| Memory and processor |
| Fabric | PowerPC IBM405 @ 266 MHz, 16 MB flash, 16 MB SRAM, 256 MB SDRAM | PowerPC IBM405 @ 266 MHz, 16 MB flash MB, 16 MB SRAM, 256 MB SDRAM |
| Interface Module | PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module | PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module |
| Management Module | PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM | PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
|
| Performance |
| Latency | < 25 µs (FIFO 64-byte packets) | < 25 µs (FIFO 64-byte packets) |
| Throughput | up to 119 million pps | up to 238 million pps |
| Routing/Switching capacity | 160 Gbps | 320 Gbps |
| Routing table size | 100000 entries | 100000 entries |
| Environment |
| Operating temperature | 41ºF to 104ºF (5ºC to 40ºC) | 41ºF to 104ºF (5ºC to 40ºC) |
| Operating relative humidity | 15% to 80% @ 104ºF (40ºC), non-condensing | 15% to 80% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 0% to 90% @ 149ºF (65ºC), non-condensing | 0% to 90% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 15000 ft. (4.57 km) | up to 15000 ft. (4.57 km) |
| Electrical characteristics |
| Maximum heat dissipation | 5119 BTU/hr (5401 kJ/hr) | 10238 BTU/hr (10801 kJ/hr) |
| Voltage | 100-125 / 200-240 VAC | 100-125 / 200-240 VAC |
| Current | 15 / 7 A | 30 / 15 A |
| Power consumption | 1500 W | 3000 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating is the worst-case theoretical maximum power number with fully loaded PoE, 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating is the worst-case theoretical maximum power number with fully loaded PoE, 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 1950 3rd edition UL 60950-1 CAN/CSA 22.2 No. 60950 CAN/CSA 22.2 No. 60950-1 EN 60825
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 1950 3rd edition UL 60950-1 CAN/CSA 22.2 No. 60950 CAN/CSA 22.2 No. 60950-1 EN 60825
|
| Notes |
| This product includes software developed by Trimble Navigation, Ltd.
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g. J4858B, J4859C) are required.
| This product includes software developed by Trimble Navigation, Ltd.
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g. J4858B, J4859C) are required.
|