| HP E6400-6XG cl Switch (J8433A) | HP E6410-6XG cl Switch (J8474A) |
|---|
| Ports |
| 6 CX4 10-GbE ports (IEEE 802.3ak Type 10Gbase-CX4)
Duplex: full only
Supports a maximum of 8 10-GbE ports, with optional module
| 6 open 10-GbE X2 transceiver slots
Supports a maximum of 8 10-GbE ports, with optional module
|
| Cabling |
| CX4 ports
Maximum distance:
- 0.5 m to 15 m using CX4 cable
- Up to 300 m using J8439A media converter using MMF
| X2 transceiver slots HP ProCurve 10-GbE X2-SC LR Optic Maximum distance:
- 9/125 µm single-mode cable = 2-10 km
- 62.5 µm multimode cable @ 160 MHz/km = 2-26 meters
- 62.5 µm multimode cable @ 200 MHz/km = 2-33 meters
- 50 µm multimode cable @ 400 MHz/km = 2-66 meters
- 50 µm multimode cable @ 500 MHz/km = 2-82 meters
- 50 µm multimode cable @ 2000 MHz/km = 2-300 meters
- 30 km (40 km using engineered link)
- 0.5 m to 15 m using CX4 cable
- Up to 300 m using J8439A media converter using MMF
HP ProCurve 10-GbE X2-SC SR Optic Maximum distance:
- 62.5 µm multimode cable @ 160 MHz/km = 2-26 meters
- 62.5 µm multimode cable @ 200 MHz/km = 2-33 meters
- 50 µm multimode cable @ 400 MHz/km = 2-66 meters
- 50 µm multimode cable @ 500 MHz/km = 2-82 meters
- 50 µm multimode cable @ 2000 MHz/km = 2-300 meters
- 30 km (40 km using engineered link)
- 0.5 m to 15 m using CX4 cable
- Up to 300 m using J8439A media converter using MMF
HP ProCurve 10-GbE X2-SC ER Optic Maximum distance:
- 30 km (40 km using engineered link)
- 0.5 m to 15 m using CX4 cable
- Up to 300 m using J8439A media converter using MMF
HP ProCurve 10-GbE X2-CX4 Transceiver Maximum distance:
- 0.5 m to 15 m using CX4 cable
- Up to 300 m using J8439A media converter using MMF
|
| Physical characteristics |
| Dimensions | 16.9(d) x 17.4(w) x 1.7(h) in. (42.93 x 44.2 x 4.32 cm) (1U height) | 16.9(d) x 17.4(w) x 1.7(h) in. (42.93 x 44.2 x 4.32 cm) (1U height) |
| Weight | 12.35 lb. (5.60 kg) | 13.56 lb. (6.15 kg) |
| Memory and processor |
| Processor | Motorola PowerPC MPC8245 @ 266 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 4 MB | Motorola PowerPC MPC8245 @ 266 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 4 MB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | < 11.7 µs (LIFO 64-byte packets) | < 11.7 µs (LIFO 64-byte packets) |
| Throughput | up to 119 million pps (64-byte packets) | up to 119 million pps (64-byte packets) |
| Routing/Switching capacity | 160 Gbps | 160 Gbps |
| MAC address table size | 16,000 entries | 16,000 entries |
| Environment |
| Operating temperature | 32°F to 131°F (0°C to 55°C); 104°F (40°C) when used with SR/LR/ER optics | 32°F to 131°F (0°C to 55°C); 104°F (40°C) when used with SR/LR/ER optics |
| Operating relative humidity | 15% to 95% @ 104°F (40°C), non-condensing | 15% to 95% @ 104°F (40°C), non-condensing |
| Non-operating/Storage temperature | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149°F (65°C), non-condensing | 15% to 95% @ 149°F (65°C), non-condensing |
| Altitude | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) |
| Acoustic | Power: 55 dB; DIN 45635T.19 per ISO 7779 @ < 77°F (25°C) | Power: 55 dB; DIN 45635T.19 per ISO 7779 @ < 77°F (25°C) |
| Electrical characteristics |
| Maximum heat dissipation | 383 BTU/hr (404 kJ/hr), including use of optional cl modules with optics | 383 BTU/hr (404 kJ/hr), including use of optional cl modules with optics |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 3 / 1.5 A | 3 / 1.5 A |
| Maximum power rating | 112 W | 120 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
|