| HP ProCurve Switch 2650 (J4899C) | HP ProCurve Switch 2650-PWR (J8165A) | HP ProCurve Switch 2626 (J4900C) |
|---|
| Ports |
| 48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
| 48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
| 24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RS-232C DB-9 console port
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
| Dimensions | 12.8(d) x 17.32(w) x 1.75(h) in. (32.51 x 43.99 x 4.45 cm) (1U height) | 18.03(d) x 17.42(w) x 1.75(h) in. (45.8 x 44.25 x 4.45 cm) (1U height) | 12.8(d) x 17.32(w) x 1.73(h) in. (32.51 x 43.99 x 4.39 cm) (1U height) |
| Weight | 9.78 lb. (4.44 kg), Fully loaded | 16.31 lb. (7.4 kg), Fully loaded | 9.15 lb. (4.15 kg), Fully loaded |
| Memory and processor |
| Processor | Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM | Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM | Motorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | < 13.3 µs (LIFO) | < 12 µs (LIFO) | < 13.3 µs (LIFO) |
| Throughput | up to 10.1 million pps | up to 10.1 million pps | up to 6.6 million pps |
| Routing/Switching capacity | 13.6 Gbps | 13.6 Gbps | 9.6 Gbps |
| MAC address table size | 8,000 entries | 8,000 entries | 8,000 entries |
| Environment |
| Operating temperature | 32ºF to 131ºF (0ºC to 55ºC) | 32ºF to 122ºF (0ºC to 50ºC) | 32ºF to 122ºF (0ºC to 50ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) |
| Acoustic | Power: 50 dB; DIN 45635T.19 per ISO 7779 | Power: 53 dB; DIN 45635T.19 per ISO 7779 | Power: 50 dB; DIN 45635T.19 per ISO 7779 |
| Electrical characteristics |
| Maximum heat dissipation | 342 BTU/hr (360.81 kJ/hr) | 2155 BTU/hr (2273.53 kJ/hr) | 342 BTU/hr (360.81 kJ/hr) |
| Voltage | 100-240 VAC | 100-240 VAC | 100-240 VAC |
| Current | 1.5 A | 7.5 / 3.5 A | 1.5 A |
| Maximum power rating | 100 W | 631 W | 100 W |
| PoE power | | 406 W | |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the power supplied by the internal power supply, it is dependent on the type and quantity of power supplies and may be supplemented with the use of a External Power Supply (EPS). | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 950 cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition UL 60950
| CSA 22.2 No. 950 cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition UL 60950