| HP ProCurve Switch 1800-8G (J9029A) | HP ProCurve Switch 1800-24G (J9028B) |
|---|
| Ports |
| 8 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
| 22 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
| Dimensions | 4.58(d) x 7.73(w) x 1.73(h) in. (11.63 x 19.63 x 4.39 cm) (1U height) | 6.74(d) x 17.42(w) x 1.73(h) in. (17.12 x 44.25 x 4.39 cm) (1U height) |
| Weight | 1.19 lb. (0.54 kg), Fully loaded | 4.32 lb. (1.96 kg), Fully loaded |
| Memory and processor |
| 1 MB flash, 64 KB SDRAM, 1 MB RAM/ROM capacity; packet buffer size: 144 KB | 2 MB flash, 64 KB SDRAM, 2 MB RAM/ROM capacity; packet buffer size: 500 KB |
| Mounting |
| Horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco racks (hardware included)
|
| Performance |
| 100 Mb Latency | < 3.9 µs (64-byte packets) | < 4.7 µs (64-byte packets) |
| 1000 Mb Latency | < 2.1 µs (64-byte packets) | < 3.0 µs (64-byte packets) |
| Throughput | up to 11.9 million pps (64-byte packets) | up to 35.7 million pps (64-byte packets) |
| Switching capacity | 16 Gbps | 48 Gbps |
| MAC address table size | 8,000 entries | 8,000 entries |
| Environment |
| Operating temperature | 32ºF to 104ºF (0ºC to 40ºC) | 32ºF to 104ºF (0ºC to 40ºC) |
| Operating relative humidity | 10% to 90% @ 104ºF (40ºC), non-condensing | 10% to 90% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 10% to 90% @ 149ºF (65ºC), non-condensing | 10% to 90% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) |
| Acoustic | Power: 0 dB no fan | Power: 0 dB no fan |
| Electrical characteristics |
| Maximum heat dissipation | 61 BTU/hr (64 kJ/hr) | 92 BTU/hr (97 kJ/hr) |
| Voltage | 100-240 VAC | 100-127 / 200-240 VAC |
| Current | 0.5 A | 0.8 / 0.4 A |
| Maximum power rating | 18 W | 27 W |
| Frequency | 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The exact input voltage and frequency rating are determined by the specific power adapter part number ordered. Please select the correct power adapter country option. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
|
| Notes |
| | Use only supported genuine ProCurve mini-GBICs with your switch.
|