| HP ProCurve 2910al-24G Switch (J9145A) | HP ProCurve 2910al-48G Switch (J9147A) | HP ProCurve 2910al-24G-PoE+ Switch (J9146A) |
|---|
| Ports |
| 20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)
1 RJ-45 serial console port
Supports a maximum of 4 10-GbE ports, with optional module
| 44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)
1 RJ-45 serial console port
Supports a maximum of 4 10-GbE ports, with optional module
| 20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)
1 RJ-45 serial console port
Supports a maximum of 4 10-GbE ports, with optional module
|
| Physical characteristics |
| Dimensions | 14.4(d) x 17.4(w) x 1.73(h) in. (36.58 x 44.2 x 4.4 cm) (1U height) | 14.4(d) x 17.42(w) x 1.73(h) in. (36.58 x 44.25 x 4.4 cm) (1U height) | 14.4(d) x 17.4(w) x 1.73(h) in. (36.58 x 44.2 x 4.39 cm) (1U height) |
| Weight | 10.92 lb. (4.95 kg) | 11.2 lb. (5.08 kg) | 12.34 lb. (5.6 kg) |
| Memory and processor |
| Processor | Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB compact flash, 512 MB SDRAM; packet buffer size: 6 MB | Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB compact flash, 512 MB SDRAM; packet buffer size: 6 MB | Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB compact flash, 512 MB SDRAM; packet buffer size: 6 MB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| 1000 Mb Latency | < 2.9 µs (FIFO 64-byte packets) | < 2.9 µs (FIFO 64-byte packets) | < 2.9 µs (FIFO) |
| 10 Gbps Latency | < 1.3 µs (FIFO 64-byte packets) | < 1.3 µs (FIFO 64-byte packets) | < 1.3 µs (FIFO) |
| Throughput | up to 95 million pps (64-byte packets) | up to 131 million pps | up to 95 million pps |
| Switching capacity | 128 Gbps | 176 Gbps | 128 Gbps |
| Routing table size | 2,000 entries | 2,000 entries | 2,000 entries |
| MAC address table size | 16,000 entries | 16,000 entries | 16,000 entries |
| Environment |
| Operating temperature | 32ºF to 131ºF (0ºC to 55ºC) | 32ºF to 131ºF (0ºC to 55ºC) | 32ºF to 131ºF (0ºC to 55ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) |
| Acoustic | Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779 | Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779 | Power: 51.5 dB, Pressure: 38.1 dB; DIN 45635T.19 per ISO 7779 |
| Electrical characteristics |
| | | Achieved Miercom Certified Green Award | |
| Description | The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz | The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz | The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
| Maximum heat dissipation | 279 BTU/hr (295 kJ/hr) | 356 BTU/hr (376 kJ/hr) | 447 BTU/hr (472 kJ/hr), max. using PoE+ |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 1.7 / 0.9 A | 2.1 / 1.1 A | 6.1 / 3.1 A |
| Idle power | 49 W | 64 W | 65 W |
| Maximum power rating | 82 W | 105 W | 490 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| EN 60950/IEC 60950 CAN/CSA 22.2 No. 60950 EN 60825 UL 60950
| EN 60950/IEC 60950 CAN/CSA 22.2 No. 60950 EN 60825 UL 60950
| EN 60950/IEC 60950 CAN/CSA 22.2 No. 60950 EN 60825 UL 60950
|
| Notes |
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|