The ProCurve 600 Redundant and External Power Supply (RPS/EPS) has 6 RPS ports and 2 EPS ports and supplies backup and Power over Ethernet power. Ports6 redundant power supply portsRestrictions: Each port can provide redundant +12 V power to a connected switch; only one port can provide power at a given time 2 external power supply ports Restrictions: Provides 50 VDC external PoE to up to two ProCurve switch devices; provides max. of 408 W full power to one device, and half power (204 W each) if connected to two devices Physical characteristicsDimensions: 12.83(d) x 17.44(w) x 1.73(h) in. (32.59 x 44.3 x 4.39 cm) (1U height)Weight: 11.78 lb. (5.34 kg), Fully loaded Mounting1U rack-mountable and wall-mountable enclosure using standard mounting hardwareEnvironmentOperating temperature: 32ºF to 131ºF (0ºC to 55ºC)Operating relative humidity: 15% to 95% @ 104ºF (40ºC), non-condensing Non-operating/Storage temperature: -40ºF to 158ºF (-40ºC to 70ºC) Non-operating/Storage relative humidity: 15% to 95% @ 149ºF (65ºC), non-condensing Altitude: up to 15,000 ft. (4.6 km) Acoustic: Noise emission LwA=59.2 dB at virtual workspace, according to DIN 45635 T.19 Electrical characteristicsDescription: The unit automatically adjusts to any voltage between 100-240 V and either 50 or 60 HzVoltage: 100-240 VAC Current: 9 / 5 A Maximum power rating: 800 W RPS power: 180 W PoE power: 408 W Frequency: 50 / 60 Hz Notes: Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. SafetyCSA 22.2 No. 60950EN 60950/IEC 60950 UL 60950 EmissionsFCC Class AVCCI Class A EN 55022/CISPR 22 Class A ImmunityEN: EN 55024, CISPR 24ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD Radiated: IEC 61000-4-3; 3 V/m EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.05 kV (signal line) Surge: IEC 61000-4-5; 1 kV/2 kV AC Conducted: IEC 61000-4-6; 3 V Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods Harmonics: EN 61000-3-2, IEC 61000-3-2 Flicker: EN 61000-3-3, IEC 61000-3-3 ManagementProvides information via port interfaces of attached devicesNotesSupported devices
|